Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
JCO Clin Cancer Inform ; 7: e2200132, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-37071027

RESUMO

PURPOSE: Modern wearable devices provide objective and continuous activity data that could be leveraged to enhance cancer care. We prospectively studied the feasibility of monitoring physical activity using a commercial wearable device and collecting electronic patient-reported outcomes (ePROs) during radiotherapy (RT) for head and neck cancer (HNC). METHODS: Patients planned for a course of external beam RT with curative intent for HNC were instructed to use a commercial fitness tracker throughout the RT course. During weekly clinic visits, physician-scored adverse events were recorded during using Common Terminology Criteria for Adverse Events version 4.0, and patients completed ePRO surveys using a clinic tablet or computer. Feasibility of activity monitoring was defined as collection of step data for at least 80% of the RT course for at least 80% of patients. Exploratory analyses described associations between step counts, ePROs, and clinical events. RESULTS: Twenty-nine patients with HNC were enrolled and had analyzable data. Overall, step data were recorded on 70% of the days during patients' RT courses, and there were only 11 patients (38%) for whom step data were collected on at least 80% of days during RT. Mixed effects linear regression models demonstrated declines in daily step counts and worsening of most PROs during RT. Cox proportional hazards models revealed a potential association between high daily step counts and both reduced risk of feeding tube placement (hazard ratio [HR], 0.87 per 1,000 steps, P < .001) and reduced risk of hospitalization (HR, 0.60 per 1,000 steps, P < .001). CONCLUSION: We did not achieve our feasibility end point, suggesting that rigorous workflows are required to achieve continuous activity monitoring during RT. Although limited by a modest sample size, our findings are consistent with previous reports indicating that wearable device data can help identify patients who are at risk for unplanned hospitalization.


Assuntos
Monitores de Aptidão Física , Neoplasias de Cabeça e Pescoço , Humanos , Projetos Piloto , Neoplasias de Cabeça e Pescoço/diagnóstico , Neoplasias de Cabeça e Pescoço/radioterapia , Medidas de Resultados Relatados pelo Paciente , Eletrônica
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...